100-1723-PK-200 MetPak Pro Weather Station

MetPak Pro Weather Station
100-1723-PK-200 MetPak Pro Weather Station
The MetPak Pro is a precision weather station, capable of monitoring the most essential weather parameters with the additional ability to connect up to four external measurement devices.
Product Details

The MetPak™ Pro, manufactured by Gill Instruments Ltd, is a precision weather station, capable of monitoring the most essential weather parameters with the additional ability to connect up to four external measurement devices.

The system combines a WindSonic ultrasonic wind speed and direction sensor, a barometric pressure sensor, and Rotronic Hygroclip temperature/humidity probe. The external junction box allows for connection of up to four additional sensors: a Pt100 temperature sensor, contact closure rain gauge, and two analogue sensors (water level sensor, pyranometer, pressure sensor, soil temperature sensor, etc).

Installation is simple using the rugged U-bolt mounting clamp, suitable for attachment to any vertical pipe from 25mm to 50mm diameter.

Specifications

Wind Measurement

  • Parameters: Wind speed & direction or U & V (Vectors)
  • Units of measure: m/s, knots, mph, kph, ft/min
  • Wind speed range: 0-60m/s (134 mph)
  • Wind speed accuracy: ±2% @12m/s
  • Wind speed resolution: 0.01m/s (0.02 mph)
  • Wind direction range: 0 to 359° - No dead band
  • Wind direction accuracy: ±3° @12m/s
  • Wind direction resolution: 1°

Air Temperature

  • Sensor: Pt100 1/3 Class B
  • Range: -35°C to +70°C
  • Accuracy: ±0.1°C
  • Resolution: 0.1°C (0.1°F)
  • Units of measure: °C or °F

Relative Humidity

  • Range: 0-100% RH
  • Accuracy: ±0.8% @23°C
  • Resolution: 0.1% RH
  • Units of measure: % RH
  • Compensated for temperature dependency

Barometric Pressure

  • Range: 600-1100hPa
  • Accuracy: ±0.5hPa
  • Resolution: 0.1hPa
  • Units of measure: hPa, mbar, mmHg, inHg
  • Compensated for temperature dependency -20°C to +70°C

Dew Point

  • Resolution: 0.1°C (0.1°F)
  • Units of measure: °C or °F
  • Accuracy: ±0.15°C (23°C ambient temp @20°C dew point)

Power Supply

  • Input voltage: 4.5Vdc to 30Vdc
  • Current: <26mA (Output 1 second) @12Vdc
  • SDI-12
    • Input Voltage: 12V nominal (9.6-16Vdc)
    • Current: <12mA Low power operation

Outputs

  • Digital outputs: RS232, RS422, RS485*, or SDI-12 (user selectable)
  • Baud rates: 9600-57600 (ASCII) or 1200 (SDI-12)
  • Protocols: ASCII or SDI-12 V1.3
  • Data output: 1s, 2s, 4s, or polled mode
  • * 2 wire point to point

Inputs

  • Analogue 1: 0-5V or 4-20mA loop or self powered
  • Analogue 2: 0-5V or 4-20mA loop or self powered
  • MetPak Pro A-D conversion: 12 bit resolution with an accuracy of ± 0.1% of reading +35µV offset
  • PRT: 4 Wire Pt100 conforms to IEC 60751
  • Rain gauge: Contact closure (tipping bucket rain gauge), capable of capturing events up to 10Hz

Environmental

  • Protection class: IP65
  • EMC: EN 61326
  • Operating temperature: -35°C to +70°C
  • Storage temperature: -40°C to +80°C
  • Operating humidity: 0% to 100% humidity

Mechanical

  • External construction: UV stabilized white thermoplastic
  • Fittings: Gloss white painted aluminum mounting bracket (with molded plastic V-block and stainless steel U-bolt), which allows attachment to a vertical pipe of any diameter between 25mm and 50mm
  • Weight: 1.1kg (including bracket)

Software

  • MetView: Display and of data logging software
  • MetSet: Configuration software
Shipping data not found, please call for more information.