The 225-41382 Relative Humidity & Temperature Probe combines a high accuracy humidity sensor and a 1000 Ohm Platinum RTD. Available with 0-1 Vdc or 4-20 mA outputs, sensors are mounted in a common junction box.
Specifications
Temperature
- Calibrated Measuring Range:
- -50 to 50 °C (suffix C)
- -50 to 150 °F (suffix F)
- Response Time: 10 seconds (without filter)
- Accuracy at 23 °C: ± 0.3 °C
- ± 0.1 °C (optional) with NIST traceable calibration
- Sensor Type: Platinum RTD
- Output Signal:
- V Option: 0-1 Vdc
- L Option: 4-20 mA
Relative Humidity
- Measuring Range: 0-100% RH
- Accuracy at 20-25 °C: ± 1% RH
- Stability: Better than ± 1% RH per year
- Response Time: 10 seconds (without filter)
- Sensor Type: Rotronic Hygromer™
- Output Signal:
- V option: 0-1 Vdc
- L option: 4-20 mA
Power Required (41382)
- 41382V: 8-30 Vdc, 7 mA @ 12 Vdc
- 41382L: 5-30 Vdc, 46 mA max
NSN 6685016306582
Downloads
- 225-41382 Data Sheet
- Manual available on request.