225-HMP155 Series Relative Humidity and Temperature Sensors

The 225-HMP155 Series of relative humidity and temperature sensors feature a new generation HUMICAP® 180R sensor with excellent stability that can withstand harsh environments. The HMP155 temperature probe’s fast response time makes it ideal for measuring changing temperatures.

The 225-HMP155 Series of relative humidity and temperature sensors feature a new generation HUMICAP® 180R sensor with excellent stability that can withstand harsh environments. The solid probe structure and sintered Teflon filter provide maximum protection against liquid water, dust, and dirt. The temperature probe's fast response time makes it ideal for measuring environments with changing temperatures. The new membrane filter speeds up RH measurement.

Extending the sensor's lifespan requires protecting it from scattered and direct sunlight, as well as precipitation. Therefore, NovaLynx recommends installing the HMP155 in a solar radiation shield or instrument shelter.

Model 225-HMP155A:

    • Humidity: 0-1 V output
    • Temperature: 0-1 V output

Model 225-500-B:

    • Humidity: 0-1 V output
    • Temperature: Integrated circuit (AD592) with 1 µA / °K output

Model 225-501-B:

    • Humidity: 0-1 V output
    • Temperature: NTC thermistor, 10 kΩ, 3% tolerance

Model 225-HMP155E: RS485 serial output

 

Specifications

225-HMP155A

  • Humidity (same as 220-HMP155D)
    • Sensing element: Thin film capacitor, with membrane filter
    • Measuring range: 0-100% RH
    • Output: 0-1 Vdc with high and low calibration adjustments
    • Accuracy: ± 1% (0-90% RH) ± 2% (90-100% RH) at 20 °C
    • Response time: 20 seconds with filter
    • Operating temperature: -40 °F to +140 °F (-40 °C to 60 °C)
    • Excitation voltage: 7-35 Vdc
    • Power consumption: < 4 mA
    • Size: 0.75 Dia x 9.45″ L
    • Weight/shipping: 10 oz/1 lb
  • Temperature (same as 225-HMP60)
    • Humidity measurement range: 10 to 90% (for which accuracy is specified)
    • Humidity accuracy: Better than ± 3% @ +68 °F (+20 °C)
    • Humidity operating range: 0-100% RH
    • Stability: ± 2% RH over 2 years
    • Temperature measurement range: -40 °F to +140 °F (-40 °C to +60 °C)
    • Temperature accuracy: 1.1 °F (± 0.6 °C) @ +68 °F (+20 °C)
    • Input power: 7-28 Vdc
    • Current consumption: 2 mA typical
    • Output signal: 0 to 1 Vdc standard; 0 to 5 Vdc available by special order
    • Housing material: Chrome-coated aluminum (IP 65)
    • Size: 0.47 Dia (12 mm) x 3″ L (80 mm), threaded M12 x 1
    • Cable length: 12″ (313 mm) with molded connector
    • Cable connector: Screw-on, 4-pin, M8 molded 1.5″ L (37 mm)

225-500-B

  • Humidity (same as 220-HMP155D and 225-HMP155A)
    • Sensing element: Thin film capacitor, with membrane filter
    • Measuring range: 0-100% RH
    • Output: 0-1 Vdc with high and low calibration adjustments
    • Accuracy: ± 1% (0-90% RH) ± 2% (90-100% RH) at 20 °C
    • Response time: 20 seconds with filter
    • Operating temperature: -40 °F to +140 °F (-40 °C to 60 °C)
    • Excitation voltage: 7-35 Vdc
    • Power consumption: < 4 mA
    • Size: 0.75 Dia x 9.45″ L
    • Weight/shipping: 10 oz/1 lb
  • Temperature (same as 210-201)
    • Sensing element: AD592CN IC transducer
    • Range: -40 °F to +140 °F (-40 °C to +60 °C)
    • Output: 1 µA / °K for supply voltages between +4 and +30 V (298.2 µA at 25 °C)
    • Accuracy: ± 0.4 °C
    • Linearity: 0.3 °C

225-501-B

  • Humidity (same as 220-HMP155D and 225-HMP155A)
    • Sensing element: Thin-film capacitor, with membrane filter
    • Measuring range: 0-100% RH
    • Output: 0-1 Vdc with high and low calibration adjustments
    • Accuracy: ± 1% (0-90% RH) ± 2% (90-100% RH) at 20 °C
    • Response time: 20 seconds with filter
    • Operating temperature: -40 °F to +140 °F (-40 °C to 60 °C)
    • Excitation voltage: 7-35 Vdc
    • Power consumption: < 4 mA
    • Size: 0.75 Dia x 9.45″ L
    • Weight/shipping: 10 oz/1 lb
  • Temperature (same as 110-WS-16T)
    • Sensing element: 10k thermistor
    • Range: -40 °F to +140 °F
    • Resolution: > 0.1 °F
    • Accuracy: ± 1 °F

Downloads