1-530-823-7185
  • PayPal
1-530-823-7185

130-200 Series Signal Conditioners

130-200 Series Signal Conditioners
130-200 Series Signal Conditioners
The 130-200 Series Signal Conditioners is a full line of field configurable conditioners useful for transmitting process control setpoints to remote PID controllers or interfacing position sensors to data acquisition and control systems.
Product Details

The 130-200 Series Signal Conditioners is a full line of field configurable conditioners useful for transmitting process control setpoints to remote PID controllers or interfacing position sensors to data acquisition and control systems. Individual modules mount on DIN rails and provide 1800 Vdc isolation between input, output, and power. The field configurable input and output offers flexible, wide range capability for DC currents, AC/DC voltage, frequency, and RTD signals. Most NovaLynx sensors will directly connect to the conditioners and provide an isolated output as selected; 4 to 20 mA, 0 to 5 or 10 Vdc, 0 to 1 mA. The Q2 version provides a two channel isolated 4-20 mA current loop in proportion to two DC inputs. The 4-20mA output is loop powered from 12 to 35 Vdc, slectable input 0-.5V, 1V, 5V, 100V, 1 mA. Signal conditioners are available for the following inputs:

  • DC voltage
  • AC voltage
  • DC output proportional to a potentiometer input
  • Frequency
  • Platinum and copper RTDs
  • Specific for high density applications

Note: All units supplied with a section of DIN rail for mounting. Refer to section on enclosures and power supplies for other suitable power sources and desktop or NEMA enclosures.

Specifications

  • Input power: 9 to 30 Vdc, 1.5 W typical, 2.5 W maximum
  • Accuracy: including linearity and hysteresis ±0.1% @ 25°C
  • Stability: Temp <±0.025%/°C
  • Isolation: 1800 Vdc between input, output and power
  • Dimensions: 4.4" (112 mm) H x 3" (76 mm) D x 0.5" (12 mm) W
  • Operating temperature range: 0 to 55°C (32 to 131°F)
  • Storage temperature range: -25 to +70°C (-13 to +158°F)
  • Operating humidity: 15 to 95% @ 45°C
  • Voltage output: 0-5 V, 0-10 V (selectable)
  • Impedance: < 10 ohms
  • Drive: 10 mA, max
  • Current output: 0-1 mA, 4-20 mA, 0-20 mA (selectable)
  • Impedance: > 100 Kohm
  • Compliance: 0-1 mA: 7.5 V, max (7.5K ohm) 4-20 mA: 12 V, max (600 ohm) 0-20 mA: 12 V, max (600 ohm)
  • Input: Each conditioner supports a wide range of specific inputs that support most of the NovaLynx sensors. Consult a sales rep for specific input specifications for each unit.
  • Mounting: Horizontal din rail mounting is recommended
  • Size: 3.54" W x 4.34" D x .50" H

130-200 Data Sheet
Manual available on request.

Shipping data not found, please call for more information.